FOR ARCHITECTS, CONSERVATION OFFICERS & SPECIFIERS

Insulate traditional buildings without trapping moisture

A vapour-permeable insulation system for solid-wall, heritage and hard-to-treat properties. Declared values, build-up detail and specification resources.

Vapour permeable Heritage compatible λ from 0.017 W/m·K Solid-wall construction WTA Merkblatt 6-4

This page exists to let you decide whether to shortlist BreatheTherm in about a minute, and to specify it without needing to call us. If something you need is missing, tell us and we will add it.

The problem with conventional insulation

Solid-wall buildings constructed before about 1919 were built to a different moisture model. Lime mortar, solid masonry and permeable finishes allow the wall to absorb moisture and release it again. There is no cavity, no membrane and no designed drainage plane; the drying capacity of the assembly is the moisture strategy.

Introducing a vapour-resistant insulation layer on the internal face changes two things at once. It lowers the temperature of the masonry behind the insulation, which increases the relative humidity within the wall, and it removes the drying path that previously ran inwards. The result is accumulation at the insulation–masonry interface.

The consequences are well documented and familiar to anyone who has surveyed a failed retrofit:

  • Interstitial condensation at the cold face of the insulation
  • Elevated moisture content in embedded timbers, particularly joist ends built into the wall
  • Frost damage and spalling where masonry cannot dry before a freeze cycle
  • Salt migration and efflorescence at the interface
  • Mould growth at thermal bridges, typically reveals and floor junctions
  • Degraded thermal performance, since wet masonry conducts heat substantially faster than dry

Traditional wall + impermeable insulation

Vapour drive meets a high-Sd layer and stops. Moisture accumulates at the interface, where it is coldest and dries slowest.

Moisture trapped

Traditional wall + BreatheTherm

Every layer is vapour-open and capillary-active. Moisture migrates through the assembly and is buffered by the hygroscopic lime-perlite matrix.

Moisture can migrate and dry

Content needed: Comparison diagram

Sammy's brief calls for a simple two-panel graphic showing vapour drive meeting an impermeable layer versus migrating through a vapour-open assembly. The panel above is a text stand-in. A drawn figure will carry far more weight with a specifier than prose.

How it compares to the common alternatives

Internal insulation options on a solid masonry wall
System Typical λ Vapour behaviour Capillary active Junction / reveal detailing
PIR board 0.022 Vapour-tight; foil facings give very high Sd No Rigid board; difficult on irregular substrates, cold bridging at fixings
Mineral wool (rockwool) on battens 0.035 Vapour-open itself, but normally installed behind a vapour control layer No Void behind the insulation is a condensation risk
Wood fibre board 0.038–0.045 Vapour-open Yes Organic; moisture tolerance is finite, and build-up depth is greater
Wood wool slab 0.065–0.085 Vapour-open Partial Usually a carrier board rather than the primary insulant
BreatheTherm (perlite) 0.064 Vapour-open, Sd 0.2–0.4 m at 50 mm Yes Applied wet, monolithic, follows irregular substrates with no void or fixings
BreatheTherm (aerogel layer) 0.017 Vapour-open, Sd 0.04–0.08 m Yes Used selectively where build depth is critically constrained

Comparator lambda values are typical published figures for the generic product category, not for any named manufacturer's product. BreatheTherm figures are our own declared values.

Why the system exists

BreatheTherm was developed by two builders rather than a materials company. Josh Tetley founded HF Limited in 2003; Greg Podolak joined in 2007, and together they launched HF Building in 2016 specialising in conservation and retrofit of period properties.

Across two decades of that work the same pattern recurred: products specified in good faith were damaging the buildings they were installed to improve. The system was developed to combine the vapour-open behaviour of traditional lime construction with thermal performance closer to that of modern insulation, rather than asking a specifier to choose between the two.

How the system works

The wall assembly

Applied directly to prepared masonry. No frame, no battens, no service void, no membrane. The absence of a cavity behind the insulation is deliberate — an air gap at the cold face of an insulation layer is where interstitial condensation collects.

  1. Existing substrate — solid brick, stone, cob, flint or timber-frame infill, prepared back to sound material
  2. PerliScratch — lime-perlite scratch coat providing a keyed, high-adhesion base
  3. PerliTherm — expanded perlite bound with hydraulic lime; the primary insulating and moisture-buffering layer
  4. AeroBond + mesh — fibre-reinforced lime-polymer adhesive and basecoat with reinforcement, replacing separate primer, adhesive and basecoat
  5. Aerogel layer — optional, used selectively where build depth is constrained
  6. PerliFinish — breathable lime finish coat

How moisture moves through the assembly

Three mechanisms operate together. Vapour diffusion moves moisture through the assembly along the vapour pressure gradient; because every layer has a low Sd value, there is no point at which that flow is arrested. Capillary transport moves liquid water back towards the drying face through the pore structure of the lime-perlite matrix, which is the mechanism conventional insulation lacks entirely. Hygroscopic buffering absorbs moisture at humidity peaks and releases it as conditions dry, damping the spikes that produce surface condensation.

Content needed: Moisture movement diagram

A section drawing showing vapour diffusion, capillary return and hygroscopic buffering across the assembly, with an indicative temperature and dewpoint profile overlaid. This is the single most persuasive graphic the page could carry.

Why perlite, and why lime

Perlite is a naturally occurring volcanic mineral. Heated, it expands and traps air, producing a lightweight aggregate that is insulating, non-combustible and open-pored. Bound in hydraulic lime it produces a render that is softer than the masonry it is applied to, vapour-open, and capillary active — three properties a cement- or gypsum-based product cannot offer simultaneously.

Lime matters for compatibility as much as for breathability. A binder harder than the substrate concentrates stress at the interface and causes the render to fail before the wall does. On historic masonry the sacrificial layer should always be the finish, not the fabric.

Why aerogel

Silica aerogel has the lowest thermal conductivity of any usable solid insulant at 0.017 W/m·K, and it remains vapour-open. Its role in the system is specific rather than general: it is used where build depth is critically constrained and perlite alone cannot reach the target U-value — window reveals, recessed frames, tight junctions and rooms where losing 50 mm from the wall face would alter the proportions unacceptably. It costs roughly five times as much per millimetre of build-up saved, so specifying it across whole elevations is rarely justified.

Technical performance

Thermal

Wall system — declared thermal and vapour values
Layer Function Thickness λ (W/m·K) Sd (m) Guide price /m²
PerliScratch Lime-perlite scratch / key coat 3–5 mm 0.080 0.02–0.04 £4.60
PerliTherm Expanded perlite insulating render, hydraulic lime bound 50 mm 0.064 0.2–0.4 £45.00
AeroBond Fibre-reinforced lime-polymer adhesive and basecoat 3–6 mm 0.12 0.02–0.04 £20.00
Aerogel layer Silica aerogel blanket for constrained build-ups 10 mm 0.017 0.04–0.08 £23.70
PerliFinish Breathable lime finish coat 20 mm — 0.10–0.20 £6.60

Guide prices are supply only, excluding VAT, and are indicative. Every build-up is specified per project. See the full cost guide.

Floor system — declared thermal and vapour values
Layer Function Thickness λ (W/m·K) Sd (m) Guide price /m²
PerliMat Vapour-permeable geotextile separator 3.5 mm n/a Vapour open £3.00
PerliBase Mineral insulating floor underbase 75–200 mm 0.045 0.3–0.6 £59.25
PerliStruct Lime-perlite structural screed / underbase 30–150 mm 0.080–0.090 0.20–0.40 from £46.00
AeroBond Fibre-reinforced lime-polymer adhesive and basecoat 5 mm 0.12 0.02–0.04 £20.00
Aerogel layer Silica aerogel blanket 5 mm 0.017 0.04–0.08 £23.25
PerliScreed Vapour-open, membrane-free floor screed 75–200 mm 0.045 0.3–0.6 £59.25

Guide prices are supply only, excluding VAT, and are indicative. Every build-up is specified per project. See the full cost guide.

Indicative U-values achieved
Substrate Build-up U-value (W/m²K)
215 mm solid brick 50 mm PerliTherm system ≈ 0.35
Constrained reveal / deep retrofit PerliTherm + 10 mm aerogel layer 0.17
Range across all specifications Varies by substrate and available depth 0.17 – 0.45

A site-specific calculation is produced for every project. Generic figures are indicative only — the same build-up on a sheltered elevation and an exposed gable will not perform identically.

Moisture

Sd values for every layer are given in the tables above. A complete 50 mm wall build-up including scratch coat, insulation, basecoat and finish has a total equivalent air layer thickness in the region of 0.35–0.7 m, which places it firmly in the vapour-open range used in WTA guidance for internal insulation of historic buildings.

Condensation risk analysis is produced per project. See hygrothermal evidence below.

Fire

Content needed: Fire classification and test evidence

Required: reaction-to-fire classification to BS EN 13501-1 for each product and for the system as installed; the test standard and notified body; any restrictions on use in buildings over 18 m or in relevant buildings under the Building Safety Act. Perlite and silica aerogel are both mineral and non-combustible in raw form, but the bound system's classification must come from actual test data. Do not publish an inferred figure.

Durability and maintenance

Content needed: Service life and maintenance schedule

Required: expected service life of the system, maintenance requirements for the lime finish, redecoration guidance including which paint systems are compatible (mineral and silicate paints only, presumably, but this needs confirming), and repairability of damaged areas.

Accreditation and third-party evidence

The system is developed to WTA Merkblatt 6-4, the German technical standard for internal insulation of historic buildings, which is the reference document conservation officers and building physicists across Europe use for this application.

Content needed: Certification status

Required: current status of BBA certification, ETA, or any other third-party product approval, including in-progress applications with expected dates. Also: which independent laboratory produced the declared lambda and Sd values, and whether Declarations of Performance are available for download. Specifiers routinely filter on this, and an honest 'ETA application submitted, expected Q2 2027' is far better than silence.

Can I specify it for my project?

Can BreatheTherm be specified for this construction?
Construction type Suitable? Notes
Solid brick walls Yes The core use case. Typically 215 mm or 330 mm solid brick with lime mortar.
Solid stone walls Yes Includes rubble-filled and Cotswold limestone construction.
Cob Yes Vapour-open throughout is essential; cob must be able to dry inwards and outwards.
Timber frame with infill Yes Wattle-and-daub and brick-nogged panels. Junction detailing is specified case by case.
Flint Yes Irregular substrate; a thicker levelling coat is usually required.
Listed buildings (all grades) Yes Subject to Listed Building Consent. We supply supporting documentation.
Conservation areas Yes Internal work does not alter external appearance, so area restrictions rarely apply.
Walls with active damp Diagnose first Rising damp, failed rainwater goods or defective pointing must be resolved before insulating.
Modern cavity walls Possible Not the intended application. Conventional measures are usually more cost-effective.
Basements below ground Case by case Depends on water table, existing tanking and drainage. Speak to the technical team.

Detail drawings & specification resources

Available on request to specifiers:

NBS specification clauses

Ready-to-use clauses for direct incorporation into your specification.

Request

CAD detail library

Standard junction details including reveals, joist ends, floor-to-wall and party walls.

Request

BIM objects

System objects for incorporation into your model.

Request

Technical data sheets

Product-level data for each layer in the wall and floor systems.

Request

Installation manual

Application sequence, curing times, tolerances and substrate preparation.

Request

Project-specific build-up

Send drawings and we will return a proposed specification with calculated U-values.

Send drawings
Content needed: Direct downloads

Every resource above is currently a mailto request, which introduces friction at exactly the point where a specifier is ready to act. Sammy's brief is explicit that this is where most manufacturer sites fail. Host the NBS clauses, CAD/DWG details, BIM objects, data sheets and installation manual as direct downloads behind an optional email capture, and replace these links. A U-value calculator would go further still.

Hygrothermal evidence

Designed around building physics rather than around a product range. Every project receives a site-specific hygrothermal assessment covering the proposed build-up, the existing wall construction, exposure and orientation, and internal moisture load.

Content needed: WUFI modelling examples

Required: two or three worked modelling examples suitable for publication — ideally a 215 mm solid brick wall, a rubble stone wall and a timber-frame infill panel. For each: total water content over a five-year run, relative humidity at the insulation–masonry interface, moisture content at an embedded joist end, and the before/after comparison against an impermeable build-up. Sammy's brief identifies this as the strongest available differentiator, and it is the section a building physicist will look at first.

Where a project carries unusual risk — a highly exposed elevation, an embedded timber floor structure, or a wall with a history of moisture ingress — modelling output can be issued directly to support a Listed Building Consent application or to satisfy a client's own technical reviewer.

Technical case studies

Grade I listed · Gloucestershire

17th century Cotswold farmhouse

Construction: solid limestone walls, cob partitions, original lime plaster.
Constraint: Historic England requirements; no loss of internal detail.
Result: 0.22 W/m²K, energy bills reduced 52%.

Victorian · Bristol

Mansion block, 12 units

Construction: solid brick, multi-occupancy.
Constraint: phased works across occupied flats.
Result: 0.19 W/m²K, bills reduced 71%, hygrothermal monitoring installed throughout, zero moisture failures recorded at 36-month review.

Period property · Cheltenham

Bedroom renovation, Upper Park Street

Construction: bare brick walls, retained lath ceiling.
Constraint: 25 mm maximum build-up.
Result: wall heat loss down 46%, ceiling down 38%, using PerliScratch, AeroBond, mesh and PerliTherm.

Content needed: Full technical case studies

Sammy's brief asks for technical case studies rather than marketing ones. For each project: building age, wall construction and thickness, existing defects identified, the specified build-up layer by layer, before and after U-values, the moisture considerations addressed, the conservation constraints, and photographs including during-works shots. Each completed study should become its own indexable page linked from here.

Technical FAQs

How does BreatheTherm compare to wood fibre systems?
Both are vapour-open and capillary active, so both are legitimate choices on a solid wall. The differences are that BreatheTherm is mineral rather than organic, is applied wet so it follows irregular substrates without a frame or void, and reaches a comparable U-value in less depth. Wood fibre is generally faster to install on a flat, regular substrate and has lower embodied carbon.
How does it compare to PIR?
PIR has a better lambda value, at roughly 0.022 against 0.064 for perlite, so it reaches a given U-value in less depth. It is also effectively vapour-tight, which on a solid wall removes the assembly's inward drying path. On a cavity-walled modern building that is not a problem. On solid masonry it is the mechanism by which internal insulation fails.
What happens if moisture enters the wall?
It moves through and dries out, which is the design intent rather than a failure mode. The lime-perlite matrix buffers liquid and vapour and returns moisture towards the drying face by capillary action. What the system cannot do is compensate for an unresolved defect — a leaking gutter, failed pointing or raised external ground level must be fixed before insulating.
Internal or external application?
The system as documented here is an internal application, which is what heritage and conservation contexts generally require. For external application on unlisted buildings, contact the technical team to discuss substrate, exposure and finish.
What thickness is typically required?
50 mm of PerliTherm plus scratch and finish coats is the standard wall build-up, giving a total added depth of around 75 mm. Where that is unacceptable, 25 mm has been used successfully on completed projects, and a 10 mm aerogel layer can be introduced to recover performance in constrained areas.
Can it be used with lime render or lime plaster?
Yes — the system is lime-based throughout and PerliFinish is itself a lime finish coat. It is compatible with existing lime plaster and with traditional lime render externally. Gypsum plaster and cement render should not be used over it.
Is hygrothermal analysis available?
Yes. A site-specific assessment is produced for every project, and modelling output can be issued to support a Listed Building Consent application or a client's technical review.
Can it be specified on a listed building?
Yes, subject to Listed Building Consent, which is required for internal works affecting character regardless of the system used. The system has been used in Grade I, Grade II* and Grade II listed buildings. More on consent.

CPD & technical support

A RIBA-accredited CPD session on moisture in traditional buildings and vapour-open retrofit is available for practices, running approximately 1.5 hours and delivered in your office or remotely. Project-specific technical advice and drawing review are available at no charge during design stage.

For architects & specifiers

Send us drawings for review, request a project-specific build-up, or book a RIBA-accredited CPD session for your practice.